  • CPU controlled, pure sine wave output.
  • Adopts intelligent IPM modules for balanced and stable output.
  • Suitable for inductive loads and mixed loads.
  • Comprehensive protection functions: overvoltage, undervoltage, over-temperature, overcurrent, short-circuit, etc.
  • Intelligent battery charging management with automatic equalization/boost charging conversion, extending battery life.
  • Fire alarm linkage supported; remote monitoring and fire control center management via RS232/RS485.
  • LCD and LED display with audio-visual fault alarm for easy maintenance.
  • Automatic transfer function enables unattended operation.
  • Energy-efficient, consumes no power when not in emergency mode.
  • No noise, no exhaust emissions, no hazards.
  • Stable and reliable performance with long service life; main unit lifespan over 20 years.

Product detail:

Applicable to emergency lighting and power supply in data centers, finance, hospitals, hotels, malls, schools, office buildings, IT facilities, exhibition centers, stadiums, subways, high-speed railways, tunnels and other buildings.

 

YJS Series (2.2–500kW) Three-phase EPS Emergency Power Supply

Category Parameter Specification
Model Range Rated Power 2.2–22kW / 25–75kW / 93–500kW
Input Voltage Three-phase four-wire + PE, 380VAC ± 20%
Frequency 50Hz ± 10%
Output Voltage Normal: Same as mains voltage; Emergency: 380VAC ± 3%
Frequency Normal: Synchronized with mains; Emergency: 50Hz ± 0.5%
Waveform Sine wave (THD ≤ 3%)
Output Circuits 1 circuit (expandable)
Circuit Type Continuous, Non-continuous, Fire-linked
Battery Type Maintenance-free
Nominal Voltage 216VDC (2.2–22kW) / 324VDC (25–75kW) / 480VDC (93–500kW)
Charging Time < 24h
Transfer Time < 5s (Customizable: ≤ 0.25s / ≤ 2.5ms / 0ms)
Backup Time 90min (Customizable)
Overload Capacity 120% continuous operation; 150% for 1min
Protection Functions Overcharge, undervoltage, overheating, overload, short-circuit, overvoltage, undervoltage protection
Efficiency ≥ 95% (emergency mode); 99% (normal mode)
Communication RS-485, Modbus-RTU; optional SNMP remote monitoring card
Display LCD or touch screen (optional)
Operating Environment Noise Level No noise in normal mode; ≤ 55dB (emergency mode); ≤ 60dB for 75kW+ units
Relative Humidity 10–90% RH (non-condensing)
Ambient Temperature -20℃ ~ 40℃
Altitude ≤ 2000m